Firmware DC Changelog ===================== 1.0.DC.35512 *** Match with HMI 1.0.0.35690 or later - Added Profibus compatibility for Concurrent CPUs - Added variable Average MW in Data Handling charts - Added WaveLog channels for raw samples (1024 SPC) - Fixed possible SendHeatSheet hang by restarting the module (heartbeat) 1.0.DC.34929 *** Match with HMI 1.0.0.34993 or later - Heat Sheet Control Mode and Control Profile reported as combination most common during power on - Added Clamp inputs and HeatSheet Clamp indicators: ClampOpenCount, ClampOpenTime, PowerOffInnerLongestClamp and PowerOffInnerLongestClampAny 1.0.DC.34489 *** Match with HMI 1.0.0.34729 or later - Added Balance setpoints to I/O map - Removed special variable BalanceUseManualOperationSetpoints, value moved to Manual Operation model 1.0.DC.34461 *** Match with HMI 1.0.0.34250 or later - Added Special Variables BalanceSPClampMin and BalanceSPClampMax to set balance limits from Special Variables - Added Special Variable BalanceUseManualOperationSetpoints to use balance setpoints from Operation inputs when running in manual - The autolower current setpoint should not be higher than the operation setpoint: Willie/Saul @ Tahara 1.0.DC.34250 *** Match with HMI 1.0.0.34250 or later - Increased range of I2HHeat and I2HCharge from 32767 to 65535 (Okayama overflowed) - Fixed logic for Disable NCC in Manual mode (since 34131) - Fixed scaling of VMEIO Encoder and Resolver (since 34131) 1.0.DC.34131 *** Match with HMI 1.0.0.34193 or later - Added SpoolPosition measurement using AI channels (IP330) - Added option to disable NCC action in Manual mode - Published HeatMWh from Nexus without having to enable its use - Changed VMEIO model scaling to support proper conversions (AI, Encoders and Resolvers) - Fixed Mean and Standard Deviation calculation for unsigned variables 1.0.DC.32997 *** Match with HMI 1.0.0.33024 or later - Added RegulatorOutOffset to IOConfiguration model (from Special Variables) 1.0.DC.32932 - Added support for the new PMC66-ADADIO2 card - Added Secondary side MWh per electrode and total calculations - Added electrode number to some alarm messages - Added RWIeu for European Union style of calculation - Added heat number prefix and digits - Improved diagnostics upload to Web Server (Maximum size of the messages queue reached. Check if Web Server is up) - Changed publication of Currents as unsigned to account for large currents (>327.67 and up to 655.35 kA) - Changed Integral defaults to slower values - Expanded data type for heat report counters to avoid overflow - Fixed DigitarcMonitor error on Concurrent CPUs - Fixed backpressure controller issues - Fixed RWI and ArcLength formulas - Fixed Nexus 1252/1450 scaling of RWH block - Fixed CaveIn2 event detection logic - Fixed problem reporting Manual ramps active for single electrode furnaces - Fixed Regulator setpoint V & I ramps when working on EAF with 2 electrodes (e.g. Ternium, Tahara) 1.0.DC.30493 - Added support for special variable UseMWHFromPrimary - Fixed Nexus 1450 MWh overflow - Changed Gain test StepDuration units to use ms 1.0.DC.30013 - Increased the timeout for FCR communications warning to 25ms - Fixed a problem that caused the second half of the FcrOutputs object words to be swapped - Added Nexus 1450 support 1.0.DC.29984 - Fixed handling of ADADIO IRQ Abort and BIST that could cause delayed measurements - Added support to FCR communication map version 2 (fuses, temperatures, status, etc.) 1.0.DC.29514 - Added Profibus protocol output for Operation ShadowMode in Base+5D bit 14 (just after SpareBlocking2) 1.0.DC.29412 - Added input Operation.ShadowMode bit to indicate when the regulator is working in shadow (1) or normal (0) 1.0.DC.29295 - Added support for Concurrent CPU - Disable NCC when Bottom Limit Switch is active - Added RegStatus ControlPowerProgramPercent (400673) and ControlSmartARCPercent (400674) for Modbus map publishing - Fixed alarm timing problem for PLC Not active, SmartARC not active, Local I/O fault and Short Electrode. Real timing was triple the configured unless a user saved the AlarmLimits model - Fixed FiringCircuitReplacement unable to reconnect after trying 120 times. - Updated documentation: RegStatus ControlPowerProgramPercent and ControlSmartARCPercent; Operation.ChargePowerOnTime_Offset units and divisor; SmartARCSupport.* divisors 1.0.DC.28281 -Added FCR Modbus Address Offset 1.0.DC.26077 - Updated the Dynamic NCC logic, now supports DynNCCMinPressure, DynNCCMaxPressure and EnableNCCDynamicOffline special variables - Fixed End of charge input from SmartARC 1.0.DC.25597 - Fixed the Nexus reconnection logic, it stopped trying after a long unsuccessful period 1.0.DC.25299 - AutoLower has a delayed start (OnDelay) - AutoLower overrides the Vsp & Isp 1.0.DC.24834 - Fixed incorrect fatal error. 1.0.DC.24330 - Fixed memory corruption occurring when an HMI was closed or lost its connection, and a user saves the model in the FurnaceType screen. 1.0.DC.23611 - Added UseFastRaise, Speed and Ramp properties to ShaperGains